FieldServer KNX Gateway
A great solution to interconnect KNX Devices on other protocol Networks like BACnet,Modbus, Lonworks, SNMP, Metasys N2, M-Bus and others.
 

 Downloads

Protocol Datasheets

KNX

Hardware Datasheets

QuickServer

Configuration Manuals

 KNX

  • FieldServer KNX Gateways - a great solution to enable two way communication between:

1.     Between a KNX network/device and a different protocol network like BACnet, Modbus, Lonworks, SNMP, Metasys N2, M-Bus.

  • FieldServer KNX Gateway models have multiple RS-485 ports, Ethernet ports and Lonworks ports (depending on the model). Hence it is possible to interconnect devices on different serial, Ethernet and Lonworks protocols together.

Popular combinations for KNX gateways

KNX to BACnet/IP Gateway

KNX to Modbus ASCii Gateway

KNX to BACnet MSTP Gateway

KNX to Modbus RTU Gateway

KNX to DF1 Gateway

KNX to Modbus TCP Gateway

KNX to DNP3 Ethernet Gateway

KNX to Notifier 3030 Gateway

KNX to DNP3 Serial Gateway

KNX to Omon FINS Gateway

KNX to Ethernet IP Gateway

KNX to OPC Gateway

KNX to HTTP Gateway

KNX to Profibus Gateway

KNX to Lonworks Gateway

KNX to Simplex 4100 Gateway

KNX to MetasysN2 Gateway

KNX to SNMP Gateway

KNX to MBus Gateway

KNX to XML Gateway


FieldServer Hardware platforms supporting KNX protocol

Device type

RS 485/232 ports

Lonworks Ports

Available Ethernet ports

Base Point count capacity

Extended Point count capacity

QuickServer

2

0

1

250

1000

QuickServer Lonworks

1

1

1

250

1000

Enhanced QuickServer

2

0

1

500

1000

Enhanced QuickServer Lonworks

1

1

1

500

1000


How to configure the FieldServer Gateway?

  • We will configure the Gateway for you based on your requirement and support you during commissioning of the Gateway, so you do not  have to worry about configuring the FieldServer Gateway.
  • However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.
  • Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).

  • In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:
    1. Node ids of the slave devices
    2. MSTP addresses/device address of the slave devices
    3. Baud rate, parity, stop bits for serial communication
    4. Scan rates
  • And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.
  • For detailed information on configuration please get in touch with us and review the configuration manual on top of this page