ProtoConvert recommends the FieldServer gateway for your KNX protocol conversion requirements. We configure and sell FieldServer gateways. We will help you find the right solution for your requirement and support you with the configuration and commissioning.
This gateway can read/write Simplex 4100 data and publish it as KNX data.
In summary, this gateway can act as:
Client/Master on the KNX network: Hence it is capable of reading data from the various KNX slave devices and writing data to them if required.
Server/Slave on the KNX network: You can use the gateway in this mode if you have a KNX master on the network which would be reading data from the gateway.
Client/Master on the Simplex 4100 network: Hence it is capable of reading data from the various Simplex 4100 devices and writing data to them if required.
|
Downloads
Protocol Datasheets
KNX
Simplex Grinell
Hardware Datasheets
QuickServer
FSB3510
Configuration Manuals
KNX
Simplex Grinell
|
FieldServer Gateways for KNX - Simplex 4100:
This table lists the different FieldServer hardware platforms which support KNX- Simplex 4100 conversion. You can make a choice depending on the number of serial/Ethernet /lonworks ports you require and the point count capacity being considered.
We will help choose the right gateway model for you. Please contact us with your detailed requirement.
Device Type
|
KNX Port
|
Serial Ports
|
Lonworks Ports
|
Ethernet Ports
|
Base Point Count Capacity
|
Extended Point Count Capacity
|
Enhanced Quick Server
|
1
|
1xRS485 or RS232
|
-
|
1
|
500
|
1000
|
Enhanced Quick Server Lonworks
|
1
|
-
|
1
|
1
|
500
|
1000
|
How to configure the FieldServer gateway?
-We will configure the gateway for you based on your requirement and support you during commissioning of the gateway, so you do not have to worry about configuring the FieldServer gateway.
-However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.
-Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).
-In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:
Node ids of the slave devices
IP addresses/device address of the slave devices
Baud rate, parity, stop bits for serial communication
Scan rates
- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.