FieldServer Building Automation Integration solutions

FieldServer gateways offer excellent solutions to enable communication between networks or devices on different building automation protocols.

Features

  • Support conversion between protocols like BACnet IP, BACnet MSTP, BACnet Ethernet, Modbus RTU, Modbus TCP, Modbus ASCii, Lonworks, SNMP, JCI Metasys N2.
  • Single/Multiple RS-232, RS-485, Lonworks and Ethernet ports  

Tested Devices

BACnet Gateway/Converter/Adapter

For connecting BACnet devices to controllers, PLCs, Building Management systems or SCADA systems that do not support BACnet protocol.

  • Supports BACnet MSTP (RS-485), BACnet IP and BACnet Ethernet
  • Supports both Client and Server (Master and Slave) mode of operation on all flavors of BACnet
  • Multiple RS-485 ports to support multiple BACnet MSTP trunks (select models)
  • Single/multiple Ethernet ports
  • Client and Server Drivers for Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), Lonworks, SNMP, Metasys N2 are available for two way communication.

Read More

Question/Purchase

Modbus Gateway/Converter/Adapter

For connecting Modbus devices to controllers, PLCs, Building Management systems or SCADA systems that do not support Modbus protocol.

  • Supports Modbus RTU (RS-232, RS-485), Modbus TCP and Modbus ASCII (RS-232, RS-485)
  • Supports both Client and Server (Master and Slave) mode of operation on all flavors of Modbus
  • Multiple RS-485/RS-232 ports to support multiple Modbus RTU trunks (select models)
  • Single/multiple Ethernet ports
  • Client and Server Drivers for BACnet (BACnet IP, BACnet MSTP), Lonworks, SNMP, Metasys N2 are available for two way communication.

Question/Purchase

Lonworks Gateway/Converter/Adapter

For connecting Lonworks devices to controllers, PLCs, Building Management systems or SCADA systems that do not support Lonworks protocol.

  • Supports Lonworks protocol over the TP/FT10 twisted pair interface
  • Supports two-way communication on Lonworks, the gateway can poll for data from other Lonworks devices on the network and also send Network Variable updates.
  • Multiple RS-485/RS-232 ports to support multiple Modbus RTU trunks (select models)
  • Single/multiple Ethernet ports

  • Client and Server Drivers for BACnet (BACnet IP, BACnet MSTP), Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), SNMP, Metasys N2 are available for two way communication.

Question/Purchase

SNMP Gateway/Converter/Adapter

For connecting SNMP devices to controllers, PLCs, Building Management systems or SCADA systems that do not support SNMP protocol.

  • Supports SNMP v1 and v2 (select models).
  • Supports SNMP v2c Traps
  • Supports both Client and Server mode of operation on SNMP
  • Capable of sending and receiving traps
  • Multiple RS-485/RS-232 ports to support multiple Modbus RTU trunks (select models)
  • Single/multiple Ethernet ports
  • Client and Server Drivers for BACnet (BACnet IP, BACnet MSTP), Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), Lonworks, Metasys N2 are available for two way communication.

Question/Purchase

JCI Metasys N2 Gateway/Converter/Adapter

For connecting JCI Metasys N2 devices to controllers, PLCs, Building Management systems or SCADA systems that do not support Metasys N2 protocol.

  • Supports JCI Metasys N2 over the RS-485 communication standard
  • Supports both Client and Server (Master and Slave) mode of operation on Metasys N2
  • Multiple RS-485 ports to support multiple Metasys N2 trunks (select models)
  • Single/multiple Ethernet ports
  • Client and Server Drivers for BACnet (BACnet IP, BACnet MSTP), Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), Lonworks, SNMP are available for two way communication.

Read more

Question/Purchase

DNP3 Gateway/Converter/Adapter

Supports DNP3 Serial and DNP3 Ethernet

For connecting DNP3 devices to controllers, PLCs, Building Management systems or SCADA systems that do not support DNP3 protocol.

  • Supports DNP3 Serial (RS-485/232) and DNP3 Ethernet
  • Supports both Client and Server (Master and Slave) mode of operation on DNP3
  • Multiple RS-485 ports to support multiple DNP3 serial trunks (select models)
  • Single/multiple Ethernet ports
  • Client and Server Drivers for BACnet (BACnet MSTP, BACnet IP), Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), Lonworks, SNMP, Metasys N2 are available for two way communication.

Read more

Question/Purchase

EthernetIP Gateway/Converter/Adapter

For connecting EthenetIP devices to controllers, PLCs, Building Management systems or SCADA systems that do not support EthernetIP protocol.

  • Supports both Client and Server mode of operation on EthernetIP
  • Multiple serial RS-485/232 ports for connecting to other field devices
  • Single/multiple Ethernet ports
  • Client and Server Drivers for BACnet (BACnet IP, BACnet MSTP), Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), Lonworks, Metasys N2 are available for two way communication.

Read more

Question/Purchase


Fire Alarm Panel Gateway/Converter/Adapter

For remote monitoring of fire alarm panels

For connecting Fire Alarm Panels to Building Automation systems, Building management systems on Modbus, BACnet, Metasys N2, Lonworks, Ethernet IP etc.

  • Solutions available for most fire alarm panels like Notifier, Gamewell, Fike Corporation, Silent Knight, Simplex Grinnell, Siemens, Firecom, Mircom, and several others.
  • Multiple RS-485/232 ports to connect to serial devices/PLCs/Controllers
  • Single/multiple Ethernet ports
  • Client and Server Drivers for BACnet (BACnet IP, BACnet MSTP), Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), Lonworks, SNMP, Etherrnet IP are available for remote monitoring

Read more

Question/Purchase

KNX Gateway/Converter/Adapter

For connecting KNX devices to controllers, PLCs, Building Management systems or SCADA systems that do not support KNX protocol.

  • Supports both Client and Server (Master and Slave) mode of operation on KNX
  • Multiple RS-485/232 ports to support multiple serial connections
  • Single/multiple Ethernet ports
  • Client and Server Drivers for BACnet (BACnet IP, BACnet MSTP), Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), Lonworks, SNMP, Metasys N2 are available for two way communication.

Read more

Question/Purchase

M-Bus Gateway/Converter/Adapter

For connecting M-Bus devices to controllers, PLCs, Building Management systems or SCADA systems that do not support M-Bus protocol.

  • Supports both Client and Server (Master and Slave) mode of operation on M-Bus
  • Multiple RS-485/232 ports to support multiple serial connections
  • Single/multiple Ethernet ports
  • Client and Server Drivers for BACnet (BACnet IP, BACnet MSTP), Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), Lonworks, SNMP, Metasys N2 are available for two way communication.

Read more

Question/Purchase

XML Gateway/Converter/Adapter

For connecting XML devices to controllers, PLCs, Building Management systems or SCADA systems that do not support XML protocol.

  • Supports both Client and Server (Master and Slave) mode of operation on XML
  • Multiple RS-485/232 ports to support multiple serial connections
  • Single/multiple Ethernet ports
  • Client and Server Drivers for BACnet (BACnet IP, BACnet MSTP), Modbus (Modbus TCP, Modbus RTU and Modbus ASCii), Lonworks, SNMP, Metasys N2 are available for two way communication.

Read more

Question/Purchase