FieldServer MBus Gateway

A great solution to interconnect MBus Devices on other protocol Networks like BACnet, Modbus, Lonworks, SNMP, Metasys N2, KNX and others.

              
 
Downloads

Protocol Datasheets

M-Bus

Hardware Datasheets

QuickServer

M-Bus InformationSheet


  • FieldServer M-Bus Gateways - a great solution to enable two way communication between:

1.     Between a M-Bus network/device and a different protocol network like BACnet, Modbus, Lonworks, SNMP, Metasys N2, KNX.

  • FieldServer M-Bus Gateway models have multiple RS-485 ports, Ethernet ports and Lonworks ports (depending on the model). Hence it is possible to interconnect devices on different serial, Ethernet and Lonworks protocols together.

Popular combinations for KNX gateways

M-BUS  to BACnet/IP Gateway


M-BUS  to Modbus ASCii Gateway

M-BUS  to BACnet MSTP Gateway

M-BUS to Modbus RTU Gateway

M-BUS  to DF1 Gateway

M-BUS to Modbus TCP Gateway

M-BUS  to DNP3 Ethernet Gateway

M-BUS  to Notifier 3030 Gateway

M-BUS  to DNP3 Serial Gateway

M-BUS  to Omon FINS Gateway

M-BUS  to Ethernet IP Gateway

M-BUS  to OPC Gateway

M-BUS  to HTTP Gateway

M-BUS  to Profibus Gateway

M-BUS  to KNX Gateway

M-BUS  to Simplex 4100 Gateway

M-BUS to Lonworks Gateway

M-BUS to SNMP Gateway

M-BUS to MetasysN2 Gateway

M-BUS  to XML Gateway


FieldServer Hardware platforms supporting M-Bus protocol

Device type

RS 485/232 ports

Lonworks Ports

Available Ethernet ports

Base Point count capacity

Extended Point count capacity

QuickServer

2

0

1

250

1000

QuickServer Lonworks

1

1

1

250

1000

Enhanced QuickServer

2

0

1

500

1000

Enhanced QuickServer Lonworks

1

1

1

500

1000


How to configure the FieldServer Gateway?

  • We will configure the Gateway for you based on your requirement and support you during commissioning of the Gateway, so you do not  have to worry about configuring the FieldServer Gateway.
  • However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.
  • Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).
  • In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:
    1. Node ids of the slave devices
    2. MSTP addresses/device address of the slave devices
    3. Baud rate, parity, stop bits for serial communication
    4. Scan rates
  • And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.
  • For detailed information on configuration please get in touch with us and review the configuration manual on top of this page