A great solution to interconnect Fire Alarm Control Panels to Building Automation Systems that are on protocols like BACnet, Modbus, Lonworks, SNMP, Metasys N2, M-Bus, KNX and others.
- FieldServer BACnet Gateways - a great solution to enable remote monitoring of Fire Alarm Control panels. Gateways provide ability to view ancillary information and not interfere with the Fire control system.
FieldServer Gateway models have multiple RS-485/232 ports, Ethernet ports and Lonworks ports (depending on the model). Hence it is possible to interconnect devices on different serial, Ethernet and Lonworks protocols together.
Popular combinations for Fire Alarm Control Panel Gateways for remote monitoring of
Panel Manufacturer
|
Panel name and solution
|
GE Security/UTC Security (formerly EST)
|
EST3 ECP Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Fike Corporation
|
Fike Cheetah Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Hochiki America
|
FireNet Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Hochiki America
|
FireNet Plus Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Gamewell-FCI by Honeywell
|
FCI Model 7100 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Gamewell-FCI by Honeywell
|
FCI Model 7200 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Gamewell-FCI by Honeywell
|
Gamewell Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Notifier by Honeywell
|
Notifier 1010/1020 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Notifier by Honeywell
|
AFP 200/300/400/500 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Notifier by Honeywell
|
CEI-ABI Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Notifier by Honeywell
|
INA Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Notifier by Honeywell
|
Italia AM6000 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Notifier by Honeywell
|
NCA2 and NFS2 3030 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Notifier by Honeywell
|
NCA Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Notifier by Honeywell
|
NFS Onyx 640 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Notifier by Honeywell
|
NFS 3030 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Silent Knight by Honeywell
|
IntelliKnight Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Mircom
|
FX2000 Fire Alarm Panel Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Simplex Grinnell
|
Simplex 4100 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Simplex Grinnell
|
Grinnell TFX Minerva Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Siemens Building Technologies
|
Siemens FireSafety MXL Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Siemens Building Technologies
|
Siemens FireFinder XLS Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Firecom
|
LSN 2000 Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
Vesda
|
LaserPlus Panel on BACnet, Modbus, Lonworks, Ethernet IP, Metasys N2, SNMP
|
FieldServer Hardware platforms for Fire Alarm Control Panel Gateways
Devicetype
|
RS 485/232 ports
|
Lonworks Ports
|
Available Ethernet ports
|
Base Point count capacity
|
Extended Point count capacity
|
FS-B2010
|
1
|
0
|
1
|
500
|
5000
|
FS-B2011
|
1
|
1
|
1
|
500
|
5000
|
FS-B2510
|
2
|
0
|
1
|
500
|
5000
|
FS-B3510
|
5
|
1
|
2
|
1000
|
10000
|
How to configure the FieldServer Gateway?
- We will configure the Gateway for you based on your requirement and support you during commissioning of the Gateway, so you do not have to worry about configuring the FieldServer Gateway.
- However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.
- Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).
- In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:
- Node ids of the slave devices
- MSTP addresses/device address of the slave devices
- Baud rate, parity, stop bits for serial communication
- Scan rates
- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.
- For detailed information on configuration please get in touch with us and review the configuration manual on top of this page
|
Downloads
Protocol Datasheets
GE Security/UTC Security
EST3 ECP
EST Quickstart
Fike Corporation
Fike Cheetah
Hochiki Americas
FireNet
FireNet Plus
Gamewell-FCI by Honeywell
FCI Model 7100
FCI Model 7200
Gamewell
Notifier by Honeywell
1010/2020
AFP 200/300/400/600
CEI-ABI
INA
Italia AM6000
NCA2 and NFS2 3030
NCA
NFS Onyx 640
NFS 3030
Silent Knight by Honeywell
IntelliKnight
Mircom
FX2000 Fire Alarm Panel
SimplexGrinnell drivers
Simplex 4100
Grinnell TFX Minerva
Siemens Building Technologies
Siemens FireSafety MXL
Siemens FireFinder XLS
Firecom
LSN2000
VESDA
LaserPlus
Hardware Datasheets
FS-2010
FS-2510
FS-3510
|