- FieldServer’s DNP3 Gateway is a great solution to enable two way communication between:
- Two different types of DNP3 Networks or devices, for example a DNP3 Serial network/Device and a DNP3 Ethernet network/device.
- Between a DNP3 Serial network/device and a different protocol network like Modbus, BACnet, Lonworks, SNMP, Metasys N2, M-Bus or KNX.
- Between a DNP3 Ethernet network/device and a different protocol network like Modbus, BACnet, Lonworks, SNMP, Metasys N2, M-Bus or KNX.
- Fieldserver DNP3 Gateway models have multiple RS-485 and RS-232 ports and an Ethernet port. Hence it is possible to interconnect devices on different serial and Ethernet protocols together.
Popular combinations for DNP3 Serial gateways
DNP3 Serial to BACnet/IP Gateway
|
DNP3 Serial to Modbus ASCii Gateway
|
DNP3 Serial to BACnet MSTP Gateway
|
DNP3 Serial to Modbus RTU Gateway
|
DNP3 Serial to DF1 Gateway
|
DNP3 Serial to Modbus TCP Gateway
|
DNP3 Serial to DNP3 Ethernet Gateway
|
DNP3 Serial to Notifier 3030 Gateway
|
DNP3 Serial to Ethernet IP Gateway
|
DNP3 Serial to Omon FINS Gateway
|
DNP3 Serial to HTTP Gateway
|
DNP3 Serial to OPC Gateway
|
DNP3 Serial to KNX Gateway
|
DNP3 Serial to Profibus Gateway
|
DNP3 Serial to Lonworks Gateway
|
DNP3 Serial to Simplex 4100 Gateway
|
DNP3 Serial to MBus Gateway
|
DNP3 Serial to SNMP Gateway
|
DNP3 Serial to Metasys N2 Gateway
|
DNP3 Serial to XML Gateway
|
Popular combinations for DNP3 Ethernet gateways
|
|
DNP3 Ethernet to BACnet/IP Gateway
|
DNP3 Ethernet to Modbus ASCii Gateway
|
DNP3 Ethernet to BACnet MSTP Gateway
|
DNP3 Ethernet to Modbus RTU Gateway
|
DNP3 Ethernet to DF1 Gateway
|
DNP3 Ethernet to Modbus TCP Gateway
|
DNP3 Ethernet to DNP3 Serial Gateway
|
DNP3 Ethernet to Notifier 3030 Gateway
|
DNP3 Ethernet to Ethernet IP Gateway
|
DNP3 Ethernet to Omon FINS Gateway
|
DNP3 Ethernet to HTTP Gateway
|
DNP3 Ethernet to OPC Gateway
|
DNP3 Ethernet to KNX Gateway
|
DNP3 Ethernet to Profibus Gateway
|
DNP3 Ethernet to Lonworks Gateway
|
DNP3 Ethernet to Simplex 4100 Gateway
|
DNP3 Ethernet to MBus Gateway
|
DNP3 Ethernet to SNMP Gateway
|
DNP3 Ethernet to Metasys N2 Gateway
|
DNP3 Ethernet to XML Gateway
|
FieldServer Hardware platforms supporting DNP3 protocol
Device type
|
RS 485/232 ports
|
Lonworks Ports
|
Available Ethernet ports
|
Base Point count capacity
|
Extended Point count capacity
|
Enhanced QuickServer
|
2
|
0
|
1
|
500
|
1000
|
Enhanced QuickServer Lonworks
|
1
|
1
|
1
|
500
|
1000
|
FS-B2010
|
1
|
0
|
1
|
500
|
5000
|
FS-B2011
|
1
|
1
|
1
|
500
|
5000
|
FS-B2510
|
2
|
0
|
1
|
500
|
5000
|
FS-B3510
|
5
|
1
|
2
|
1000
|
10000
|
How to configure the FieldServer Gateway?
- We will configure the Gateway for you based on your requirement and support you during commissioning of the Gateway, so you do not have to worry about configuring the FieldServer Gateway.
- However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.
- Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).
- In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:
- Node ids of the slave devices
- MSTP addresses/device address of the slave devices
- Baud rate, parity, stop bits for serial communication
- Scan rates
- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.
- For detailed information on configuration please get in touch with us and review the configuration manual on top of this page