ProtoConvert recommends the FieldServer gateways for
your BACnet protocol conversion requirements. We configure and sell
FieldServer gateways. We will help you find the right solution for your
requirement and support you with the configuration and commissioning.
This gateway can read BACnet data from your BACnet MSTP devices and publish it as Lonworks data.
It can also write to the BACnet MSTP devices.
This gateway can also do the reverse, read Lonworks data and publish it as BACnet MSTP data.
It can also write to the Lonworks devices.
In summary, this gateway can act as:
Client/Master on the BACnet MSTP network: Hence it is capable of reading data from the various BACnet
slave devices and writing data to them if required.
Server/Slave on the BACnet MSTP network: You can use the gateway in this mode if you have a BACnet MSTP
master on the network which would be reading data from the gateway.
Client/Master on the
Lonworks network: Hence it is capable of reading data from the various
Lonworks devices and writing data to them if required.
Server/Slave on the Lonworks
network: The gateway can be configured to be a server of data values,
hence another Lonworks client can read data from the gateway and write
data into the gateway.
|
Downloads
Protocol DataSheets
BACnet MSTP
LonWorks
Hardware datasheets
QuickServer
Enhanced QuickServer
FS-B3510
Reference Manuals
BACnet MSTP
LonWorks
FieldServer Configuration manual
|
Question/Purchase

FieldServer Gateways for BACnet MSTP - LonWorks:
This table lists the different FieldServer hadware platforms which
support BACnet MSTP - LonWorks conversion. You can make a choice depending
on the number of serial/ethernet /lonworks ports you require and the
point count capacity being considered.
We will help choose the right gateway model for you. Please contact us with your detailed requirement.
Device Type
|
Serial Ports
|
Lonworks Ports
|
Ethernet Ports
|
Base Point Count Capacity
|
Extended Point Count Capacity
|
QuickServer Lonworks
|
1xRS-485 |
1 |
1 |
250 |
1000 |
Enhanced QuickServer Lonworks
|
1xRS485 or RS232
|
1
|
1 |
500
|
1000 |
FS-B3510 |
2xRS-485
2xRS-232
1xRS-232 System Port
|
1 |
2 |
1000 |
10000 |
-We will configure the gateway for you based on your requirement and
support you during commissioning of the gateway, so you do not have to
worry about configuring the FieldServer gateway.
-However, it is very helpful to know how to configure the devices.
All the required tools and supporting product manuals with be provided
completely free of cost with your purchase.
-Configuration of the FieldServer is done using a '.csv' file. This
file can be edited using any text editor (example Microsoft excel).
-In this file we need to enter information for the Client and Server
side interfaces of the FieldServer. This includes but is not limited to:
Node ids of the slave devices
IP addresses/device address of the slave devices
Baud rate, parity, stop bits for serial communication
Scan rates
- And finally we need to create an internal mapping that would map
each data value read on the client side to a data value on the server
side.
-For detailed information on configuration please get in touch with us and review the configuration manual on top of this page