ProtoConvert recommends the FieldServer gateway for your BACnet protocol conversion requirements. We configure and sell FieldServer gateways. We will help you find the right solution for your requirement and support you with the configuration and commissioning.
This gateway can read Notifier 3030 data and publish it as BACnet IP data.
It can also write to the Notifier 3030 devices.
In summary, this gateway can act as:
Client/Master on the BACnet IP network: Hence it is capable of reading data from the various BACnet slave devices and writing data to them if required.
Server/Slave on the BACnet IP network: You can use the gateway in this mode if you have a BACnet IP master on the network which would be reading data from the gateway.
Client/Master on the Notifier 3030 network: Hence it is capable of reading data from the various Notifier 3030 devices and writing data to them if required.
|
Downloads
Protocol datasheet
BACnet
Notifier 3030
Manuals
BACnet IP
Notifier 3030
FieldServer Manual
Hardware Gateways
Enhanced Quickserver
FS-B3510
|
Question/Purchase
FieldServer Gateways for BACnet IP - Notifier 3030:
This table lists the different FieldServer hadware platforms which support BACnet IP - Notifier 3030 conversion. You can make a choice depending on the number of serial/ethernet /lonworks ports you require and the point count capacity being considered.
We will help choose the right gateway model for you. Please contact us with your detailed requirement.
Device Type
|
Serial Ports
|
Lonworks Ports
|
Ethernet Ports
|
Base Point Count Capacity
|
Extended Point Count Capacity
|
Enhanced QuickServer
|
2
|
0
|
1 |
500
|
1000 |
FS-B3510 |
2xRS-485
2xRS-232
1xRS-232 System Port
|
1 |
2 |
1000 |
10000 |
How to configure the FieldServer gateway?
-We will configure the gateway for you based on your requirement and support you during commissioning of the gateway, so you do not have to worry about configuring the FieldServer gateway.
-However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.
-Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).
-In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:
Node ids of the slave devices
IP addresses/device address of the slave devices
Baud rate, parity, stop bits for serial communication
Scan rates
- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.
-For detailed information on configuration please get in touch with us and review the configuration manual on top of this page