QuickServer - BACnet/IP - JCI Metasys N2

The FS-QS-1010-0122 QuickServer provides a cost-effective, easy to use interface from BACnet/IP to JCI Metasys N2.

 

 

Downloads

Protocol Datasheets

BACnet IP

JCI Metasys N2

Gateway Datasheets

QuickServer

Configuration Manuals

BACnet IP

JCI Metasys N2


Question/Purchase

  • This gateway can read data from your Metasys N2 devices and publish it as BACnet IP data.
  • It can also write to the Metasys N2 devices.
  • This gateway can also do the reverse, read BACnet IP data and publish it as Metasys N2 data.
  • It can also write to the BACnet IP devices.

In summary, this gateway can act as:

Master on the Metasys N2 network: Hence it is capable of reading data from the various Metasys N2 slave devices and writing data to them if required.

Slave on the Metasys N2 network: You can use the gateway in this mode if you have a Metasys N2 master on the network which would be reading data from the gateway.

Master on the BACnet IP network: Hence it is capable of reading data from the various BACnet IP devices and writing data to them if required.

Slave on the BACnet IP network: The gateway can be configured to be a server of data values; hence another BACnet IP client can read data from the gateway and write data into the gateway.

 

QuickServer Key Features:

  • BACnet Testing Laboratory (BTL)Mark
  • Ability to interface up to 250 points of common BAS protocols
  • Multi-configuration capability; specific configurations selectable via DIP switches or software
  • Flat panel mount standard, DIN rail mount option
  • DIP switches to select baud rate or node ID on the fly

BACnet/IP driver:

  • Driver type: Client or Server
  • Data Link layer: BACnet IP, (Annex J)
  • Connection type: BACnet/IP Internet Protocol (IP), 10/100BaseT, BBMD supported
  • BACnet COV support for fast data communication while reducing traffic over a BACnet network
  • Data types supported:
    • AI - Analog Input Object
    • AO - Analog Output Object
    • AV - Analog Value Object
    • BI - Binary Input Object
    • BO - Binary Output Object
    • BV - Binary Value Object
    • MI - Multi-state Input Object
    • MO - Multi-state Output Object
    • MV - Multi-state Value Object

JCI Metasys N2 driver:

  • Supports communication with following devices or classes of devices when acting as a Client
    • N2OPEN-compliant devices
    • VMA 1400 series
    • DX9100 and XT9100
  • Driver type: Client or Server
  • Connection type: RS-485 (two wire, half duplex)
  • Baud rates: 9600
  • Devices tested:
    • UNT
    • VMA1410,
    • VMA1420
    • DX9100 with XT9100 extension
    • NCM (FieldServer as N2Open server)
    • VAV
    • AHU
    • VND
      • Metasys is a trademark of Johnson Controls
      • BACnet is a trademark of ASHRAE

 

How to configure the FieldServer gateway?

-We will configure the gateway for you based on your requirement and support you during commissioning of the gateway, so you do not  have to worry about configuring the FieldServer gateway.

-However, it is very helpful to know how to configure the devices. All the required tools and supporting product manuals with be provided completely free of cost with your purchase.

-Configuration of the FieldServer is done using a '.csv' file. This file can be edited using any text editor (example Microsoft excel).

-In this file we need to enter information for the Client and Server side interfaces of the FieldServer. This includes but is not limited to:

                Node ids of the slave devices

                IP addresses/device address of the slave devices

                Baud rate, parity, stop bits for serial communication

                Scan rates

- And finally we need to create an internal mapping that would map each data value read on the client side to a data value on the server side.

-For detailed information on configuration please get in touch with us and review the configuration manual on top of this page